Version | Release Date | Features |
Pro-AIS2 v1.24.02 | Oct 2022 | Update to ProAIS2 to correct a Windows DLL error |
Pro-AIS2 v1.14 | Mar 2019 |
|
Pro-AIS2 v1.10 | Mar 2018 |
|
v2.03 (040200.02.03.00) | Jan 2020 |
|
v2.02 (040200_02_02_00) | June 2017 |
AIS650 will report this as 040200.02.02.00 Note: The software update also consists of a PC USB driver update that must also be applied to the PC that the Class B is used with regularly. Failure to update the USB driver software on the PC may result on the device not being recognised, even if the device itself has received the software update. |
v1.15 (040200_01_15_01) | Oct 2015 |
AIS650 will report this as 040200.01.15.01 Note: The software update also consists of a PC USB driver update that must also be applied to the PC that the Class B is used with regularly. Failure to update the USB driver software on the PC may result on the device not being recognised, even if the device itself has received the software update. |
v1.10 (040200_01_10_03) | Aug 2014 |
|
v1.7 (040200_010711) | April 2013 |
|
v1.03.02 | April 2013 |
|
v1.6 (040200_01_06_02) | Oct 2012 |
|
v1.4 (040200_01_04_00) | 2012 |
|
v1.3 (040200_01_03_00) | 2011 |
|
Some Raymarine products contain software code developed by third parties that are covered by open source GPL and LGPL software license agreements. You can view the third party license agreements by visiting the Manuals section of our website.
To access the open source GPL and LGPL licensed executables click here
There are 2 methods of updating the software on your AIS650:
Below you will find instructions for both methods. None of the methods will delete any data or settings in your AIS unit. You can change some settings using the ProAIS2 software available to download from the main AIS650 software page. If you require your MMSI to be changed/reset, then you must contact your local Raymarine agent, who can arrange this for you.
Note: this will not change any User/Vessel details inside the AIS650, MMSI, or Vessel Type.
1 - Applying the Software Requirements:
Extract the contents of the AIS650 SD card download .zip file to your hard drive. Copy the two files from the .zip file to a blank SD card.
Note: For further confirmation that the update has been successful, it is possible to check the software version on the Class B by connecting it ProAIS2 and checking the “Diagnostics” tab. If the update was successful, then the latest software version will be displayed.
Note: this will not change any User/Vessel details inside the AIS650, MMSI, Vessel Type.
Applying the Software Updater Requirements:
Important Note: It is important to note that this software update also consists of a PC USB driver update that must also be applied to the PC that the Class B AIS is used with regularly. Failure to update the USB driver software on the PC may result in the device not being recognized, even if the device itself has received the software update.
This process is automated by the installer software, and the update should be carried out using the PC normally used with the AIS device. The AIS Updater Software package itself relies on the user following simple on-screen instructions to allow the update to be installed.
Please read the welcome notice on this pop-up and then select “Start” when you are ready to begin the process. The Updater software program will then guide the user through the process one step at a time.
Note: For further confirmation that the update has been successful, it is possible to check the software version on the Class B by connecting it ProAIS2 and checking the “Diagnostics” tab. If the update was successful, then the updated software version will be displayed.