ST70+ Software

ST70+ Software

Software download and update information for the Raymarine ST70+:

  • Applicable for:  ST70+
  • Software Version: v1.08
  • Release Date: October 2010
  • Replaces: v1.06, v1.04
  • Important Notes: 4 software files are required; (Instrument App, Pilot App & Bootloader together with the relevant autorun file for the MFD you are using. Bootloader must be installed first, then the Pilot App and Instrument App after.
MFDDownload Link
A SeriesDownload Here
E  ClassicDownload Here
C WideDownload Here
E WideDownload Here
G SeriesDownload V2 Here
Download V4 Here
a/c/e/gS SeriesDownload V6 Here
Download V7 Here

Important Terms of downloading software

Firmware update processes are done at your own risk. Before initiating the update process be sure to backup and make copies of all important files.

If the firmware process is interrupted your product may not function properly, therefore do not interrupt the process and ensure the unit is on a reliable power supply. Damage caused by incomplete upgrades will not be covered by Raymarine warranty.

By Downloading the software, you agree to these terms.

Software history


VersionRelease DateFeatures
v1.08Oct 2010
  • Stops the display resetting either after a software upgrade or after running for some time.
  • Corrections to the calculation of Ground Wind Direction.
  • Changes to static heading. Now does not default to Magnetic.
  • The SOG Analogue dial now auto scales correctly.
  • Corrects Pilot Display intermittent crashes.
  • Corrects upgrade fails with ST70 Data Pods on bus.
  • Stops the ST70+ Display resetting when an ST70 Display is set to Polish Language.
v1.06May 2010
  • The display can develop a fault condition that causes the unit to reset. This normally occurs after power cycling the display. 
  • The display can cause the selected units to drop back to default and the display can also lose the Keyboard setup.
  • Datum tables have been updated to remove ambiguous datum’s and to align with ST70 and MFDs.
v1.04July 2009
  • Initial Release


Open Source GPL/LGPL

Some Raymarine products contain software code developed by third parties that are covered by open source GPL and LGPL software license agreements. You can view the third party license agreements by visiting the Manuals section of our website.

To access the open source GPL and LGPL licensed executables click here

Software Update Information and Instructions for Raymarine Instrument Displays

This software update FAQ relates to the following products:

  • i50
  • i60
  • i70s
  • p70s
  • STng Converter
  • ITC-5

If you have performed the a, c, e, eS, gS or AXIOM Series MFD update recently you may not need to perform this update. Please check your device software.

PLEASE READ

Please fully read this page before attempting to update your Raymarine System. This page contains each step for you to sucessfully update your Raymarine system

IMPORTANT TERMS OF DOWNLOADING SOFTWARE

Firmware update processes are done at your own risk. Before initiating the update process be sure to backup and make copies of all important files.

If the firmware process is interrupted your product may not function properly, therefore do not interrupt the process and ensure the unit is on a reliable power supply. Damage caused by incomplete upgrades will not be covered by Raymarine warranty.

By Downloading the software, you agree to these terms.

Stage 1: Populating the mSD Flash Memory Card (or CF Card) with the MFD Software

Note: To avoid potentially corrupting the data on your Navionics chart card, DO NOT copy software update files to your Navionics chart card and DO NOT back up waypoint/route/track data to your Navionics chart card. MicroSD cards are commonly available in most stores selling consumer electronics products. Waypoint, route, track data, and system configuration data can be stored on a microSD memory card which also contains software update files.

  • You are NOT required to update the products software versions sequentially. For example, you can go from application v1.04 to v1.35, however you may require a bootcode upgrade first.
  • The mSD (Micro SD) memory cards used with a/c/e/eS/gS Series MFDs should have a memory capacity of no less than 1GB and no more than 32GB.
  • The mSD card should be formatted to FAT32. (External link: Instructions)
  1. Insert a compatible Flash memory card into the computer's memory card reader or into a memory card reader which has been interfaced to the computer.
  2. Select the appropriate software download for your product
  3. Upon completion of the download, click on the "Downloads folder" (or the folder where your Internet Browser has been directed to save downloaded files), to open it
  4. If the downloaded file is a .ZIP file, extract the contents of the .zip file - (if it is an .ISO file, go to STEP 6) 
    Note: Only unzip the main ZIP file that is downloaded. Do not attempt to open the files contained within the ZIP file as these may have extensions such as .dob .pkg .sh .sh.sig .iso or .zip with various file names. If you attempt to open these files you may see an error as they are designed to update your Raymarine products and not for use in a windows, Apple or Linux PC.
Software Screenshot
  1. Copy the contents of the main zip file to the Root of the Flash card (Root is the first level you access when selecting the Flash).
  2. If the Download is an ISO file, do not try to open the file. Instead just copy the whole ISO file over to the root of the mSD card.
    1. Note: Some products may have both a Bootloader and an Application ISO file (such as the VHF Radios). Do not copy these onto the same mSD card at the same time, otherwise the upgrade will not work. The Bootloader ISO must be on a seperate uSD card. Please review the Radio Upgrade instructions HERE for further information.
Software screenshot
  1.  Important: Make sure the files are not in any folders on the card
    1. For example: if your computer has assigned Removable Disk (E:) to your memory card reader/writer, then the software update files should be copied directly to Removable Disk (E:), not to any folders created on the memory card.
  2. Remove the memory card from the computer's memory card reader.

Stage 2: The update method

Information about the a, c, e, eS, gS and AXIOM Series update using ISO files

The a, c, e, eS, gS-Series software download or AXIOM Series software download, now contains the latest version of software for the following peripherals:

  • Adaptors – ST1-STNG Converter, ECI-100, iTC-5
  • AIS - AIS700
  • Fishfinders – CP100, CP200, CP370, CP470, CP570, RVX1000
  • GPS - RS130, RS150
  • Instruments – i50, i60, i70, iTC-5, p70
  • Pilots – Evolution ACU, Evolution EV-1, p70, p70R
  • RMK-9 / RMK-10
  • Radar - Quantum, Magnum
  • VHF - Ray50, Ray60, Ray70 (not the 2nd Station Handset)

These are grouped together as ISO files

Once the Master MFD has been updated, usually any connected MFD or peripheral will be updated as well.

If you have performed the update recently on the MFD, you may not need to perform this update. Please check if you require the update.

Updating the Product using a, c, e, eS, gS or AXIOM Series MFD's using ISO files

Note: If we do not offer an ".ISO" download package for upgrading via an a/c/e/eS/gS or AXIOM MFD, it is because the product cannot be upgraded using this method. Please contact Raymarine for alternative solutions.

  1. Please make sure that the product to be upgraded, and the MASTER Multifunction Display (MFD) have both been interfaced to one another via a powered and properly terminated SeaTalkNG backbone, that the Product and MASTER MFD have been powered ON, and have completed startup initialization before starting the update procedure.
    1. Note, if upgrading an ECI-100, the Engine side (Devicenet side) of the product has to have power connected to it as well.
  2. Place the mSD card with the ISO file product software into the Master MFD (while it is powered on)
  3. If you are not presented with a pop-up box within a short period of time, then enter the following menu:
    1. From the Home Screen, press Set-Up > Maintenance > Check Card for updates
  4. Follow the on screen instructions until you are presented with a table of connected products
  5. Ensure that the product/s you wish to update are ticked (i.e. the ST1 to STng converter needs to be ticked)
  6. Click on the Install now button located in the bottom right corner of the screen.
  7. MFD will show update % progress and eventually "Upgrade Complete" for the product/s
  8. Once all products have completed, remove the mSD card from the MFD and Power Cycle the system.
  9. Finally, please verify that all software is now up to date by going to the "checking the software versions..." section below:

Checking the software versions of your Raymarine products using a, c, e, eS or gS Series MFD

  • The MFD's and peripherals software version may be verified via the command sequence:
  • [Home screen] Setup > Maintenance > Diagnostics > Select Device 

Please note: You will only see Raymarine devices that are connected on SeaTalkNG and RayNet only. Other devices may not be listed

Updating the Product with a Legacy display (A Series Classic, E Series Classic, C Series Wide, E Series Wide, G Series) or an a/c/e/eS/gS MFD using PKG files

Note: If we do not offer a ".PKG" download package for upgrading via a legacy MFD, it is because the product cannot be upgraded using this method. Please contact Raymarine for alternative solutions. 

  1. Power OFF the MASTER MFD.
  2. Please make sure that the Product to be upgraded, and the MASTER Multifunction Display (MFD) have both been interfaced to one another via a powered and properly terminated SeaTalkNG backbone, that the Product to be upgraded is powered ON, and has completed startup initialization before starting the update procedure.
    1. Note, if upgrading an ECI-100, the Engine side (Devicenet side) of the product has to have power connected to it as well. 
  3. Insert the memory card containing the PKG product software update file, and the relevant Autorun file/s into the MASTER MFD’s memory card reader.
    1. All PKG and Autorun files must be in the root of the Memory card, not within a Folder or Zip file.
  4. Power ON the MASTER MFD.
  5. After the MFD has booted to its Raymarine Software Upgrade Utility screen, select the software upgrade package from the Upgrade Packages Available list.
  6. Press the UPGRADE REMOTE UNIT function key.
  7. Press the UPGRADE REMOTE UNIT ON ST2 (It may also say STNG depending on the current version of software you are using).
  8. Use the Trackpad to highlight the unit you wish to update and press the UPGRADE UNIT softkey.
    1. Note, If the RS130 is not listed then try power cycling the RS130 off and on again (turning the SeaTalk1 or SeaTalkNG power off/on). Try this 3-4 times to see if communication can be obtained and you see the RS130 appear. Then select the RS130 in the list to be upgraded.
  9. When the progress indicator's Overall bar reaches 100%, the Device's software will have been upgraded.
  10. Remove the CF memory card from the MFD's memory card reader.
  11. If you have just upgraded your RS130 bootloader or VHF Radio bootloader, then you will need to upgrade the Application to restore operation.
    1. Once bootloader has been loaded, follow steps 1-10 above to load in the application for the product, then progress to step 12 below.
  12. Power cycle the whole system.