Firmware update processes are done at your own risk. Before initiating the update process be sure to backup and make copies of all important files.
If the firmware process is interrupted your product may not function properly, therefore do not interrupt the process and ensure the unit is on a reliable power supply. Damage caused by incomplete upgrades will not be covered by Raymarine warranty.
By Downloading the software, you agree to these terms.
Version | Release Date | Features |
v4.20 | Sept 2010 |
|
v4.12 | April 2010 |
|
v4.11 | Sept 2009 |
|
v4.10 | March 2007 |
|
v3.16 | ### |
|
v3.14 | ### |
|
v3.12 | ### |
|
Some Raymarine products contain software code developed by third parties that are covered by open source GPL and LGPL software license agreements. You can view the third party license agreements by visiting the Manuals section of our website.
To access the open source GPL and LGPL licensed executables click here
This FAQ relates to the following products:
Autopilots | Instruments | SeaTalkhs/Raynet/SeaTalkNG connected | Using one of the following MFD's to update the software: |
p70 p70R Evolution EV1/EV2 ACU100 / ACU200 / ACU300 / ACU400 SPX-5 SPX-10 SPX-30 SPX-40 SPX-CAN SPX-DIO SPX-SOL ST70 Pilot Head ST70+ Pilot Keypad - Sail ST70+ Pilot Keypad - Power | i70 i60 i50 ITC-5 ST70 Instrument Head ST70+ ST70+ Instrument Keypad ST70+ Pilot Keypad - Sail ST70+ Pilot Keypad - Power | SeaTalkNG to SeaTalk one Converter ECI100 SR150 DSM30/DSM300 CP370 / CP450 / CP570 Ethernet Radome HD Radome HD/SHD Open Array | a Series - a65, a67 c Series - c95, c97, c125. c127. e Series - e7, e7D, e95, e97, e125, e127, e165 gS Series - gS95, gS125, gS165 A Series -A50, A50D, A57, A57D, A70, A70D E Series Classic - E80, E120 C Series Wide - C90w, C120w, C140w E Series Wide - E90w, E120w, E140w |
The following procedure addresses how one would populate a Flash memory card (Compact Flash or mSD) with software update files to update one of the listed remote products using a supported Multifunction Display (MFD) and then use this memory card to update the Remote Device software.
Please note that product software updates may revert some of the Device configuration settings back to the default settings. As such, it is recommended that customers make note of the configuration settings so that they may be used to reconfigure the Device settings after the Device software has been updated. With regards to the SPX Autopilots the device must be recalibrated after any update has been performed.
The next stage is to update the remote device using your MFD. Please choose the appropriate instructions below depending on what MFD you are using to perform the update. This update must be performed on all connected devices of the same model in the system. If there is connected devices of the same model in the system with different software versions you may experience spurious issues.
Note: Software updates do not have to be performed sequentially unless stated. It is fine to update from version 2.00 to version 5.00 and miss both version 3.00 and 4.00 if you have not previously installed them. All necessary information for the units to operate are included in the latest update.
This firmware update process is done at your own risk. Before initiating the update process be sure to backup and make copies of all important files.
If the firmware process is interrupted your product may not function properly, therefore do not interrupt the process and ensure the unit is on a reliable power supply. Damage caused by incomplete upgrades will not be covered by Raymarine warranty.
By Downloading the software, you agree to these terms.
Instructions using an A Series, C Series or E Series Wide/Classic MFD
Menu > Diagnostics > About display
i70/p70: Menu > Set-Up > Diagnostics > About Display
i50/i60: Press and hold buttons 1 and 2 until the software version is displayed in intermediate cal. This is the Cal level after User Cal is shown
a,c,e or gS Series MFD: If you have a a,c,e or gS Series MFD you can view software versions of all compatible devices. On the MFD:
[Home screen] Setup > Maintenance> Diagnostics > Select Device. Please note it will only show devices known to the MFD. Some devices may not be listed.