New, low prices on Axiom chartplotters!
See All DealsNew! Raymarine + Florida Marine Tracks
Learn moreThe HyperVision 3D transducer provides a multitude of frequencies all within a single housing. Capable of simultaneously supplying RealVision 3D, DownVision, SideVision and Conical High Frequency CHIRP, this is the only shallow-to-medium depth transducer you'll ever need.
1.2MHz HyperVision DownVision and SideVision frequencies offer the utmost in clarity and lifelike sonar imaging.
Transom Mount
Deadrise Angles: 0 - 90°
General Specifications | |
---|---|
Material | Plastic |
Max Depth | 3D: 300 / Down: 600 / Port: 300 / Starboard: 300 / Conical: 900 |
Frequency | 1.2 MHz CHIRP / 350 kHz CHIRP / 200 kHz High CHIRP |
Beam Width | 3D: 180° / Down: 60° / Conical: 25° |
Records | Depth / Temperature |
Hull Material | Fiberglass / Metal |
Cable Length | 19 Ft. / 6 M. |
HyperVision | |
---|---|
350 kHz (Standard) range | RealVision 3D = 0.6 M (2 ft) to 91 m (300 ft), SideVision = 0.6 M (2 ft) to 91 m (300 ft) each side, DownVision = 0.6 M (2 ft) to 183 m (600 ft) |
1.2 MHz (Hyper) range | RealVision 3D = 0.6 M (2 ft) to 38 m (125 ft), SideVision = 0.6 M (2 ft) to 38 m (125 ft) each side, DownVision = 0.6 M (2 ft) to 38 m (125 ft) |
Sonar channels | Conical high CHIRP sonar, RealVision 3D (Hyper), RealVision 3D (Standard), SideVision (Hyper), SideVision (Standard), DownVision (Hyper), DownVision (Standard) |
200 kHz range | Conical high CHIRP sonar = 0.6 M (2 ft) to 274 m (900 ft) |
Frequencies | 1.2 MHz CHIRP, 350 kHz CHIRP, 200 kHz CHIRP |
Power | 1.2 MHz (Hyper) = 1000 W, 350 kHz (Standard) = 700 W, 200 kHz (Conical high CHIRP sonar) = 100 W |
Physical | |
---|---|
Dimensions | Length: 224.99 mm (8.86 in), Height: 112.69 mm (4.44 in), Width: 76.00 mm (2.99 in) |
Cable length | HV-100: 6 m (19.69 ft) fitted cable |
Weight (unboxed) | 1.05 kg (2.31 lb) |
Environmental | |
---|---|
Waterproof rating | IPx6 (surfaces exterior to hull only), IPx7, IPx8 |
Storage temperature range | 20° C (23° F) to + 70° C (158° F) |
Operating temperature range | -2° C (28.4° F) to + 55° C (131° F) |
Conformance | |
---|---|
Standards | EN 60945:2002, IEC 28846:1993, EMC Directive 2014/30/EU, Australia and New Zealand: C-Tick, Compliance Level 2 |
1 | Transom bracket |
2 | Bracket fixing screws (4.2x19 mm A4 stainless steel) x3 |
3 | M5x10 hex bolt (A4 stainless steel) |
4 | M5 washer (A4 stainless steel) |
5 | Hanger bracket |
6 | Escutcheon plate (used when routing cable through transom or a bulkhead) |
7 | Adjustment slot washers x2 |
8 | Transducer with 6 m (19.69 ft) fitted cable |
9 | Escutcheon plate fixings (#8x13 SUS316) x4 |
10 | Cable clips x3 |
11 | Cable clips x3 |
12 | Documentation |
13 | M6x70 hex bolt (A4 stainless steel) |
14 | M6 washer (A4 stainless steel) |
15 | M6 locking nut |